Switching power supply(SMPS, SPS, Switch power supply)S-60 Series | | | Switching power supply(SMPS, SPS, Switch power supply) 1.Low price and high reliability 2.105 output capacitor3.AC input power suitable for the world4.High efficiency and low operation temperature5.Soft-start current can reduce the AC input impact effectively6.With short-circuit and overload protection 7.Compact size, light weight8.100% full-load burning test9.Installed with EMI filter, minimum wave | Model Specification | S-60-5 | S-60-12 | S-60-15 | S-60-24 | DC output voltage | 5V | 12V | 15V | 24V | Output voltage error (Note2) | ±2% | ±1% | ±1% | ±1% | Rated output current | 10A | 4.2A | 3.4A | 2.1A | Output current rage | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A | Wave and noise(Note3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | Load stability(Note5) | ±1% | ±0.5% | ±0.5% | ±0.5% | DC output power | 50W | 50.4W | 50.4W | 50.4W | Efficiency | 71% | 78% | 78% | 82% | Adjustable range for DC voltage | ±10,-5% | ±10% | ±10% | ±10% | AC input voltage range | 85132VAC/170264VACselected by switch | Input current | 2A/115V 1A/230V | AC impulse current | Cold-start current 30A/115V 60A/230V | Leakage current | <1mA/240VAC | Overload protection | 105%150%TypeTOLDBACK Reset: auto recovery | Over-voltage protection | | High-temperature protection | | Temperature coefficient | ±0.03%(050) | Setup rise hold up time | 200ms,100ms,30ms | Vibration | 10500Hz,2G 10min./1cycle,Period for 60min,Each axes | Withstand voltage | Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms | Working temperature and humidity | -10+60,20%90%RH | Store temperature and humidity | -20+85,10%95RH | Overall dimension | 0.56Kgs | Safety standards | UL1012 TUV EN60950IEC950,UL1950Approved | EMC standards | CLSPR22(EN55022),IEC801-234,IEC555-2 Verification | Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2311must be knocked down. |
|
|